{"id":10053,"date":"2025-07-07T10:45:24","date_gmt":"2025-07-07T02:45:24","guid":{"rendered":"https:\/\/chinagode.com\/?p=10053"},"modified":"2025-08-06T09:10:55","modified_gmt":"2025-08-06T01:10:55","slug":"cach-ket-noi-2-bo-bien-tan-song-song","status":"publish","type":"post","link":"https:\/\/chinagode.com\/vi\/blog\/how-to-connect-2-inverters-in-parallel\/","title":{"rendered":"C\u00e1ch k\u1ebft n\u1ed1i 2 b\u1ed9 bi\u1ebfn t\u1ea7n song song: H\u01b0\u1edbng d\u1eabn t\u1eebng b\u01b0\u1edbc cho h\u1ec7 th\u1ed1ng n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi"},"content":{"rendered":"<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_9228dd-3a, .wp-block-kadence-advancedheading.kt-adv-heading10053_9228dd-3a[data-kb-block=\"kb-adv-heading10053_9228dd-3a\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_9228dd-3a mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_9228dd-3a[data-kb-block=\"kb-adv-heading10053_9228dd-3a\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_9228dd-3a img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_9228dd-3a[data-kb-block=\"kb-adv-heading10053_9228dd-3a\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_9228dd-3a wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_9228dd-3a\">In large-scale or scalable <a href=\"https:\/\/chinagode.com\/solutions\/residential-pv-system\/\" data-type=\"page\" data-id=\"6463\">photovoltaic (PV) systems<\/a>, the output power of a single inverter is limited due to constraints such as power switch device capacity. To meet the demand of higher power loads, it is common practice to connect multiple inverters in parallel to combine their output power\u2014an effective solution for achieving higher overall system capacity.<\/p>\n\n\n<style>.kb-image10053_d8c00d-b0 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image10053_d8c00d-b0\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"1200\" height=\"900\" src=\"https:\/\/chinagode.com\/wp-content\/uploads\/2025\/07\/gode-multi-inverter-parallel-connection-malaysia-energy-storage-project.webp\" alt=\"gode-multi-inverter-parallel-connection-malaysia-energy-storage-project\" class=\"kb-img wp-image-10069\" srcset=\"https:\/\/chinagode.com\/wp-content\/uploads\/2025\/07\/gode-multi-inverter-parallel-connection-malaysia-energy-storage-project.webp 1200w, https:\/\/chinagode.com\/wp-content\/uploads\/2025\/07\/gode-multi-inverter-parallel-connection-malaysia-energy-storage-project-768x576.webp 768w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure><\/div>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_d1ec5a-34, .wp-block-kadence-advancedheading.kt-adv-heading10053_d1ec5a-34[data-kb-block=\"kb-adv-heading10053_d1ec5a-34\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_d1ec5a-34 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_d1ec5a-34[data-kb-block=\"kb-adv-heading10053_d1ec5a-34\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_d1ec5a-34 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_d1ec5a-34[data-kb-block=\"kb-adv-heading10053_d1ec5a-34\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_d1ec5a-34 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_d1ec5a-34\">This article takes the <a href=\"https:\/\/chinagode.com\/products\/on-off-grid-5-6kw-12kw-solar-hybrid-inverter-with-mppt\/\" data-type=\"products\" data-id=\"5273\">GODE 5.6KW-01P<\/a> solar inverter as an example to systematically explain how to perform a parallel connection of two inverters. It covers preparation, wiring procedures, communication configuration, common mistakes to avoid, and summarizes the pros and cons of inverter parallelization\u2014helping users build a stable, efficient, and expandable PV power system.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_2b34a7-0e, .wp-block-kadence-advancedheading.kt-adv-heading10053_2b34a7-0e[data-kb-block=\"kb-adv-heading10053_2b34a7-0e\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_2b34a7-0e mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_2b34a7-0e[data-kb-block=\"kb-adv-heading10053_2b34a7-0e\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_2b34a7-0e img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_2b34a7-0e[data-kb-block=\"kb-adv-heading10053_2b34a7-0e\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading10053_2b34a7-0e wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_2b34a7-0e\">1. Preliminary Checks and Preparation<\/h2>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_5f732d-0e, .wp-block-kadence-advancedheading.kt-adv-heading10053_5f732d-0e[data-kb-block=\"kb-adv-heading10053_5f732d-0e\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_5f732d-0e mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_5f732d-0e[data-kb-block=\"kb-adv-heading10053_5f732d-0e\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_5f732d-0e img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_5f732d-0e[data-kb-block=\"kb-adv-heading10053_5f732d-0e\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_5f732d-0e wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_5f732d-0e\">1.1 Verify Inverter Compatibility<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_011b29-e1, .wp-block-kadence-advancedheading.kt-adv-heading10053_011b29-e1[data-kb-block=\"kb-adv-heading10053_011b29-e1\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_011b29-e1 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_011b29-e1[data-kb-block=\"kb-adv-heading10053_011b29-e1\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_011b29-e1 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_011b29-e1[data-kb-block=\"kb-adv-heading10053_011b29-e1\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_011b29-e1 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_011b29-e1\">Using GODE 5.6KW-01P as an example:<br>Inverter A: 5.6KW-01P<br>Inverter B: 5.6KW-01P<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_3153ba-2e, .wp-block-kadence-advancedheading.kt-adv-heading10053_3153ba-2e[data-kb-block=\"kb-adv-heading10053_3153ba-2e\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_3153ba-2e mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_3153ba-2e[data-kb-block=\"kb-adv-heading10053_3153ba-2e\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_3153ba-2e img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_3153ba-2e[data-kb-block=\"kb-adv-heading10053_3153ba-2e\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_3153ba-2e wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_3153ba-2e\">Ensure both solar inverters are of the same model and specifications, especially with consistent voltage, current, and frequency ratings. Incompatibility may lead to system failures or equipment damage. The GODE 5.6KW-01P supports up to 6 units in parallel, using RS485 or CAN communication protocols.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_1197ba-38, .wp-block-kadence-advancedheading.kt-adv-heading10053_1197ba-38[data-kb-block=\"kb-adv-heading10053_1197ba-38\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_1197ba-38 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_1197ba-38[data-kb-block=\"kb-adv-heading10053_1197ba-38\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_1197ba-38 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_1197ba-38[data-kb-block=\"kb-adv-heading10053_1197ba-38\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_1197ba-38 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_1197ba-38\">We recommend using inverters from the <a href=\"https:\/\/dl.acm.org\/doi\/10.1145\/3386415.3387037\" target=\"_blank\" rel=\"noopener\">same brand, model<\/a>, firmware version, and rated power to maximize compatibility and system efficiency.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_b6d586-22, .wp-block-kadence-advancedheading.kt-adv-heading10053_b6d586-22[data-kb-block=\"kb-adv-heading10053_b6d586-22\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_b6d586-22 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_b6d586-22[data-kb-block=\"kb-adv-heading10053_b6d586-22\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_b6d586-22 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_b6d586-22[data-kb-block=\"kb-adv-heading10053_b6d586-22\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_b6d586-22 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_b6d586-22\">1.2 Prepare Required Cables and Tools<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_638e73-bd, .wp-block-kadence-advancedheading.kt-adv-heading10053_638e73-bd[data-kb-block=\"kb-adv-heading10053_638e73-bd\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_638e73-bd mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_638e73-bd[data-kb-block=\"kb-adv-heading10053_638e73-bd\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_638e73-bd img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_638e73-bd[data-kb-block=\"kb-adv-heading10053_638e73-bd\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_638e73-bd wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_638e73-bd\">Sufficient length and gauge of AC cables, communication lines, grounding wires, etc.<br><strong>Tools<\/strong>: screwdrivers, wrenches, electrical tape, multimeter, and other commissioning tools.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8bd3-b5, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8bd3-b5[data-kb-block=\"kb-adv-heading10053_ad8bd3-b5\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8bd3-b5 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8bd3-b5[data-kb-block=\"kb-adv-heading10053_ad8bd3-b5\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8bd3-b5 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8bd3-b5[data-kb-block=\"kb-adv-heading10053_ad8bd3-b5\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading10053_ad8bd3-b5 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_ad8bd3-b5\">2. Step-by-Step Inverter Parallel Operation<\/h2>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_c5538b-4c, .wp-block-kadence-advancedheading.kt-adv-heading10053_c5538b-4c[data-kb-block=\"kb-adv-heading10053_c5538b-4c\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c5538b-4c mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_c5538b-4c[data-kb-block=\"kb-adv-heading10053_c5538b-4c\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c5538b-4c img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_c5538b-4c[data-kb-block=\"kb-adv-heading10053_c5538b-4c\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_c5538b-4c wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_c5538b-4c\">Step 1: Install Communication Cables<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Define the master inverter (Master) and the slave inverter (Slave)<\/li>\n\n\n\n<li>Use RS485, CAN bus, or manufacturer-specific ports to interconnect the two inverters<\/li>\n\n\n\n<li>For RS485: use a daisy-chain configuration and add 120\u03a9 termination resistors at both ends for stable communication<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_c47a1a-60, .wp-block-kadence-advancedheading.kt-adv-heading10053_c47a1a-60[data-kb-block=\"kb-adv-heading10053_c47a1a-60\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c47a1a-60 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_c47a1a-60[data-kb-block=\"kb-adv-heading10053_c47a1a-60\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c47a1a-60 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_c47a1a-60[data-kb-block=\"kb-adv-heading10053_c47a1a-60\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_c47a1a-60 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_c47a1a-60\">Step 2: Connect Inverter Output Terminals<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_891e14-54 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_891e14-54\">Connect the output terminals of both inverters with correct phase sequence and polarity. Typical inverter output labels include &#8220;L&#8221; (Live), &#8220;N&#8221; (Neutral), and &#8220;PE&#8221; (Earth). Ensure phase consistency to avoid circulating current (loop current) issues.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Inverter A Live (L) \u2192 Distribution box L terminal<\/li>\n\n\n\n<li>Inverter B Live (L) \u2192 Same L terminal<\/li>\n\n\n\n<li>Inverter A Neutral (N) \u2192 Distribution box N terminal<\/li>\n\n\n\n<li>Inverter B Neutral (N) \u2192 Same N terminal<\/li>\n\n\n\n<li>Ground terminals of both inverters \u2192 Common grounding point<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_2f530e-ab, .wp-block-kadence-advancedheading.kt-adv-heading10053_2f530e-ab[data-kb-block=\"kb-adv-heading10053_2f530e-ab\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_2f530e-ab mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_2f530e-ab[data-kb-block=\"kb-adv-heading10053_2f530e-ab\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_2f530e-ab img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_2f530e-ab[data-kb-block=\"kb-adv-heading10053_2f530e-ab\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_2f530e-ab wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_2f530e-ab\"><strong>Wiring Standards:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Use compatible terminals for secure and reliable connections<\/li>\n\n\n\n<li>All inverters should share the same grounding system to prevent interference or leakage risks<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_891e14-54 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_891e14-54\">Step 3: Connect to Battery Bank (if applicable)<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_891e14-54[data-kb-block=\"kb-adv-heading10053_891e14-54\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_891e14-54 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_891e14-54\">Connect the output terminals of both inverters with correct phase sequence and polarity. Typical inverter output labels include &#8220;L&#8221; (Live), &#8220;N&#8221; (Neutral), and &#8220;PE&#8221; (Earth). Ensure phase consistency to avoid circulating current (loop current) issues.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>If the system includes energy storage, connect both inverters to the same battery bank<\/li>\n\n\n\n<li>Install battery isolators, fuses, or breakers for safety<\/li>\n\n\n\n<li>Ensure battery voltage matches the inverter input range, or startup failure\/damage may occur<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_c1f6fe-13, .wp-block-kadence-advancedheading.kt-adv-heading10053_c1f6fe-13[data-kb-block=\"kb-adv-heading10053_c1f6fe-13\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c1f6fe-13 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_c1f6fe-13[data-kb-block=\"kb-adv-heading10053_c1f6fe-13\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c1f6fe-13 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_c1f6fe-13[data-kb-block=\"kb-adv-heading10053_c1f6fe-13\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_c1f6fe-13 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_c1f6fe-13\">Step 4: Connect PV Modules<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Option A (recommended): Connect each inverter to a separate solar PV array<\/li>\n\n\n\n<li>Option B: Use a combiner box to evenly distribute PV strings across both inverters<\/li>\n\n\n\n<li>Monitor MPPT input current to avoid overload<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_a3d3b1-90, .wp-block-kadence-advancedheading.kt-adv-heading10053_a3d3b1-90[data-kb-block=\"kb-adv-heading10053_a3d3b1-90\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_a3d3b1-90 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_a3d3b1-90[data-kb-block=\"kb-adv-heading10053_a3d3b1-90\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_a3d3b1-90 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_a3d3b1-90[data-kb-block=\"kb-adv-heading10053_a3d3b1-90\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_a3d3b1-90 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_a3d3b1-90\">Connect the output terminals of both inverters with correct phase sequence and polarity. Typical inverter output labels include &#8220;L&#8221; (Live), &#8220;N&#8221; (Neutral), and &#8220;PE&#8221; (Earth). Ensure phase consistency to avoid circulating current (loop current) issues.<\/p>\n\n\n<style>.kb-image10053_151802-17 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image10053_151802-17\"><figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"1200\" height=\"800\" src=\"https:\/\/chinagode.com\/wp-content\/uploads\/2025\/07\/solar-inverter-parallel-connection-diagram.webp\" alt=\"solar-inverter-parallel-connection-diagram\" class=\"kb-img wp-image-10073\" srcset=\"https:\/\/chinagode.com\/wp-content\/uploads\/2025\/07\/solar-inverter-parallel-connection-diagram.webp 1200w, https:\/\/chinagode.com\/wp-content\/uploads\/2025\/07\/solar-inverter-parallel-connection-diagram-768x512.webp 768w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure><\/div>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86, .wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86[data-kb-block=\"kb-adv-heading10053_f917dc-86\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86[data-kb-block=\"kb-adv-heading10053_f917dc-86\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86[data-kb-block=\"kb-adv-heading10053_f917dc-86\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_f917dc-86 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_f917dc-86\">Step 5: Power-On and Test<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Double-check all wiring<\/li>\n\n\n\n<li>Power on the master inverter first, verify voltage\/current\/frequency output<\/li>\n\n\n\n<li>Power on the slave inverter and ensure synchronization<\/li>\n\n\n\n<li>Confirm in the monitoring interface that both inverters are in parallel mode and working in coordination<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86, .wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86[data-kb-block=\"kb-adv-heading10053_f917dc-86\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86[data-kb-block=\"kb-adv-heading10053_f917dc-86\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_f917dc-86[data-kb-block=\"kb-adv-heading10053_f917dc-86\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_f917dc-86 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_f917dc-86\">Step 6: Load Testing<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Connect the system to real loads (motors, lights, etc.)<\/li>\n\n\n\n<li>Observe for stable operation, absence of alarms, voltage spikes, or inverter faults<\/li>\n\n\n\n<li>Check whether current sharing between inverters is balanced<\/li>\n\n\n\n<li>If anomalies occur, inspect communication setup, voltage consistency, and cable quality<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_1ee693-ae, .wp-block-kadence-advancedheading.kt-adv-heading10053_1ee693-ae[data-kb-block=\"kb-adv-heading10053_1ee693-ae\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_1ee693-ae mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_1ee693-ae[data-kb-block=\"kb-adv-heading10053_1ee693-ae\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_1ee693-ae img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_1ee693-ae[data-kb-block=\"kb-adv-heading10053_1ee693-ae\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading10053_1ee693-ae wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_1ee693-ae\">3. Common Mistakes to Avoid in Inverter Parallel Setup<\/h2>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_dccfa6-c7, .wp-block-kadence-advancedheading.kt-adv-heading10053_dccfa6-c7[data-kb-block=\"kb-adv-heading10053_dccfa6-c7\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_dccfa6-c7 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_dccfa6-c7[data-kb-block=\"kb-adv-heading10053_dccfa6-c7\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_dccfa6-c7 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_dccfa6-c7[data-kb-block=\"kb-adv-heading10053_dccfa6-c7\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_dccfa6-c7 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_dccfa6-c7\">Mixing Different Brands or Firmware Versions<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_ad8847-ef wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_ad8847-ef\"><strong>Issue<\/strong>: Using inverters with different models, brands, or voltage levels may cause uneven load sharing, inefficiency, or damage<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_8b4d7a-0d, .wp-block-kadence-advancedheading.kt-adv-heading10053_8b4d7a-0d[data-kb-block=\"kb-adv-heading10053_8b4d7a-0d\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_8b4d7a-0d mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_8b4d7a-0d[data-kb-block=\"kb-adv-heading10053_8b4d7a-0d\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_8b4d7a-0d img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_8b4d7a-0d[data-kb-block=\"kb-adv-heading10053_8b4d7a-0d\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_8b4d7a-0d wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_8b4d7a-0d\"><strong>Solution<\/strong>: Always use identical models with the same firmware and specifications<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_c93184-8a wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_c93184-8a\">AC Phase Connection Errors<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_c93184-8a wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_c93184-8a\"><strong>Issue<\/strong>: Incorrect wiring between phase and neutral, or loose terminals, can result in malfunction or reduced efficiency<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_c93184-8a[data-kb-block=\"kb-adv-heading10053_c93184-8a\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_c93184-8a wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_c93184-8a\"><strong>Solution<\/strong>: Turn off all power before wiring; double-check terminal markings; ensure firm, insulated, and correct connections<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_caa745-eb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_caa745-eb\">Skipping Communication Configuration<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_caa745-eb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_caa745-eb\"><strong>Issue<\/strong>: Without proper communication setup, the inverters can\u2019t exchange data, leading to instability<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_caa745-eb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_caa745-eb\"><strong>Solution<\/strong>: Use RS485, CAN, or the manufacturer\u2019s dedicated interfaces, configure master-slave roles, and verify communication status<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_2ef758-80, .wp-block-kadence-advancedheading.kt-adv-heading10053_2ef758-80[data-kb-block=\"kb-adv-heading10053_2ef758-80\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_2ef758-80 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_2ef758-80[data-kb-block=\"kb-adv-heading10053_2ef758-80\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_2ef758-80 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_2ef758-80[data-kb-block=\"kb-adv-heading10053_2ef758-80\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_2ef758-80 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_2ef758-80\">Insufficient Ventilation or Tight Installation<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_807baa-8b, .wp-block-kadence-advancedheading.kt-adv-heading10053_807baa-8b[data-kb-block=\"kb-adv-heading10053_807baa-8b\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_807baa-8b mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_807baa-8b[data-kb-block=\"kb-adv-heading10053_807baa-8b\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_807baa-8b img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_807baa-8b[data-kb-block=\"kb-adv-heading10053_807baa-8b\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_807baa-8b wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_807baa-8b\"><strong>Issue<\/strong>: Installing inverters in poorly ventilated, confined spaces may cause overheating and performance degradation<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_caa745-eb[data-kb-block=\"kb-adv-heading10053_caa745-eb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_caa745-eb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_caa745-eb\"><strong>Solution<\/strong>: Allow adequate spacing for airflow, cooling, and maintenance to ensure long-term reliable operation<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading10053_ad8847-ef wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_ad8847-ef\">4. Advantages and Disadvantages of Parallel Inverter Systems<\/h2>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_ad8847-ef[data-kb-block=\"kb-adv-heading10053_ad8847-ef\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_ad8847-ef wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_ad8847-ef\">Mixing Different Brands or Firmware Versions<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_083cb1-24 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_083cb1-24\">4.1 Advantages<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_083cb1-24 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_083cb1-24\"><strong>Increased Capacity and Output:<\/strong><br>Multiple inverters connected in parallel combine their power, e.g., two GODE 5.6KW-01P inverters deliver 11.2kW, ideal for high-consumption households.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_083cb1-24 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_083cb1-24\"><strong>Improved Reliability:<\/strong><br>In case one inverter fails or is under maintenance, others continue operating to maintain power supply.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_083cb1-24 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_083cb1-24\"><strong>Scalability:<\/strong><br>Easily expand the system by adding more inverters without redesigning the whole infrastructure, saving time and cost.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_083cb1-24 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_083cb1-24\"><strong>Extended Lifespan:<\/strong><br>Load is distributed among units, reducing stress on individual inverters and increasing their service life.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_c73cfa-38, .wp-block-kadence-advancedheading.kt-adv-heading10053_c73cfa-38[data-kb-block=\"kb-adv-heading10053_c73cfa-38\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c73cfa-38 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_c73cfa-38[data-kb-block=\"kb-adv-heading10053_c73cfa-38\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_c73cfa-38 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_c73cfa-38[data-kb-block=\"kb-adv-heading10053_c73cfa-38\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h3 class=\"kt-adv-heading10053_c73cfa-38 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_c73cfa-38\">4.2 Disadvantages<\/h3>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_22b33a-4d, .wp-block-kadence-advancedheading.kt-adv-heading10053_22b33a-4d[data-kb-block=\"kb-adv-heading10053_22b33a-4d\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_22b33a-4d mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_22b33a-4d[data-kb-block=\"kb-adv-heading10053_22b33a-4d\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_22b33a-4d img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_22b33a-4d[data-kb-block=\"kb-adv-heading10053_22b33a-4d\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_22b33a-4d wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_22b33a-4d\"><strong>Higher Cost:<\/strong><br>Two inverters are usually more expensive than one of equal capacity. Additional cables and accessories add to the cost.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_90a2a9-83, .wp-block-kadence-advancedheading.kt-adv-heading10053_90a2a9-83[data-kb-block=\"kb-adv-heading10053_90a2a9-83\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_90a2a9-83 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_90a2a9-83[data-kb-block=\"kb-adv-heading10053_90a2a9-83\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_90a2a9-83 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_90a2a9-83[data-kb-block=\"kb-adv-heading10053_90a2a9-83\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_90a2a9-83 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_90a2a9-83\"><strong>Maintenance Complexity:<\/strong><br>More devices mean more points of failure and longer troubleshooting times.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_30b055-78, .wp-block-kadence-advancedheading.kt-adv-heading10053_30b055-78[data-kb-block=\"kb-adv-heading10053_30b055-78\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_30b055-78 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_30b055-78[data-kb-block=\"kb-adv-heading10053_30b055-78\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_30b055-78 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_30b055-78[data-kb-block=\"kb-adv-heading10053_30b055-78\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_30b055-78 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_30b055-78\"><strong>Greater Control Complexity:<\/strong><br>Parallel operation requires precise current sharing control to prevent circulating currents. Existing methods like current detection, master-slave, decentralized logic, or droop control are still imperfect\u2014posing risks of losses, instability, or power interruptions.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_083cb1-24[data-kb-block=\"kb-adv-heading10053_083cb1-24\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_083cb1-24 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_083cb1-24\">While inverter parallel operation offers significant advantages in capacity, reliability, and scalability, it demands high standards in inverter selection, communication setup, wiring accuracy, and system coordination. By carefully following standard procedures and using compatible components, users can minimize risks such as circulating current or voltage imbalance and ensure safe, long-term parallel operation.<\/p>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading10053_dfcf64-2e, .wp-block-kadence-advancedheading.kt-adv-heading10053_dfcf64-2e[data-kb-block=\"kb-adv-heading10053_dfcf64-2e\"]{font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading10053_dfcf64-2e mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading10053_dfcf64-2e[data-kb-block=\"kb-adv-heading10053_dfcf64-2e\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading10053_dfcf64-2e img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading10053_dfcf64-2e[data-kb-block=\"kb-adv-heading10053_dfcf64-2e\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<p class=\"kt-adv-heading10053_dfcf64-2e wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading10053_dfcf64-2e\">For projects involving multi-inverter systems, we recommend choosing inverters with native parallel support, complete communication interfaces, and thorough documentation to reduce technical complexity and ongoing maintenance costs.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>H\u01b0\u1edbng d\u1eabn c\u00e1ch k\u1ebft n\u1ed1i 2 b\u1ed9 bi\u1ebfn t\u1ea7n n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi song song \u0111\u1ec3 t\u0103ng c\u00f4ng su\u1ea5t \u0111\u1ea7u ra trong h\u1ec7 th\u1ed1ng PV. H\u01b0\u1edbng d\u1eabn n\u00e0y bao g\u1ed3m c\u00e1c b\u01b0\u1edbc k\u1ebft n\u1ed1i d\u00e2y, thi\u1ebft l\u1eadp giao ti\u1ebfp, ki\u1ec3m tra t\u01b0\u01a1ng th\u00edch v\u00e0 c\u00e1c l\u1ed7i th\u01b0\u1eddng g\u1eb7p c\u1ea7n tr\u00e1nh.<\/p>","protected":false},"author":1,"featured_media":10069,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[25,134],"tags":[142,141],"class_list":["post-10053","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-solar-inverter","tag-installation-guide","tag-solar-knowledge"],"acf":[],"taxonomy_info":{"category":[{"value":25,"label":"Blog"},{"value":134,"label":"Solar Inverter"}],"post_tag":[{"value":142,"label":"Installation Guide"},{"value":141,"label":"Solar Knowledge"}]},"featured_image_src_large":["https:\/\/chinagode.com\/wp-content\/uploads\/2025\/07\/gode-multi-inverter-parallel-connection-malaysia-energy-storage-project.webp",1200,900,false],"author_info":{"display_name":"godestore","author_link":"https:\/\/chinagode.com\/vi\/author\/godestore\/"},"comment_info":0,"category_info":[{"term_id":25,"name":"Blog","slug":"blog","term_group":0,"term_taxonomy_id":25,"taxonomy":"category","description":"Check out our blog for expertise and information on green energy.","parent":0,"count":46,"filter":"raw","cat_ID":25,"category_count":46,"category_description":"Check out our blog for expertise and information on green energy.","cat_name":"Blog","category_nicename":"blog","category_parent":0},{"term_id":134,"name":"Solar Inverter","slug":"solar-inverter","term_group":0,"term_taxonomy_id":134,"taxonomy":"category","description":"Learn everything about solar inverter\u2014from working principles to model comparison and system integration tips.","parent":25,"count":10,"filter":"raw","cat_ID":134,"category_count":10,"category_description":"Learn everything about solar inverter\u2014from working principles to model comparison and system integration tips.","cat_name":"Solar Inverter","category_nicename":"solar-inverter","category_parent":25}],"tag_info":[{"term_id":142,"name":"Installation Guide","slug":"installation-guide","term_group":0,"term_taxonomy_id":142,"taxonomy":"post_tag","description":"The installation guide provides best practices, safety standards, and technical procedures for installing solar inverters, batteries, and energy storage systems.","parent":0,"count":3,"filter":"raw"},{"term_id":141,"name":"Solar Knowledge","slug":"solar-knowledge","term_group":0,"term_taxonomy_id":141,"taxonomy":"post_tag","description":"Explore solar energy fundamentals and PV system science in our solar knowledge section. Ideal for engineers, professionals, and clean energy advocates.","parent":0,"count":6,"filter":"raw"}],"_links":{"self":[{"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/posts\/10053","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/comments?post=10053"}],"version-history":[{"count":18,"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/posts\/10053\/revisions"}],"predecessor-version":[{"id":11077,"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/posts\/10053\/revisions\/11077"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/media\/10069"}],"wp:attachment":[{"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/media?parent=10053"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/categories?post=10053"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chinagode.com\/vi\/wp-json\/wp\/v2\/tags?post=10053"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}